Mindray pm7000 pm8000 pm9000 Monitor Pasien Printer Paket Standar Normal

Detail produk:
Tempat asal: Asli
Nama merek: Mindray
Nomor model: pm7000 pm8000 pm9000
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 pc
Harga: Negotiate
Kemasan rincian: Paket Standar Normal / Paket Individu
Waktu pengiriman: 1-3 hari kerja
Syarat-syarat pembayaran: T/T, Western Union, Paypal
Menyediakan kemampuan: 10 pcs per minggu
  • Informasi Detail
  • Deskripsi Produk

Informasi Detail

Jenis produk: Patient Monitor Printer Nama merek: Mindray
Harga: Negotiate Syarat-syarat pembayaran: T/T, Western Union atau Paypal
Pengiriman Waktu: 1-3 hari kerja Transportasi: DHL, EMS, UPS, FedEx
Pengepakan: normal standar Garansi: Garansi 90 Hari
Menyoroti:

mesin rumah sakit

,

peralatan medis rumah sakit

Deskripsi Produk

Printer untuk Monitor Pasien Mindray pm7000 pm8000 pm9000 Printer dengan Bekas

Nama Item: Printer

Merek: Mindray

Model yang Berlaku: PM-7000 PM-8000 PM-9000

Lebih banyak suku cadang untuk monitor Mindray:

Mindray PM memberikan monitor pasien suku cadang
mainboard (motherboard) papan tombol ditekan
Sumber Daya listrik Papan NIBP (pompa)
printer Papan EKG
papan tegangan tinggi papan oksigen darah


Lingkup Bisnis Perusahaan Kami

  • Monitor EKG, Monitor janin, Defibrillator, Elektrokardiograf, Oksimeter untuk perbaikan dan aksesori untuk penjualan.

  • Mainboard, Power Stripe / Panel, Layar Sentuh, Layar tampilan, Papan Tombol, Modul EKG / Oksimeter / Darah untuk memperbaiki dan menjual.

  • Medical Patient Monitor / Electrocardiograph untuk leasing, pemeliharaan, jaminan perbaikan dan pertukaran.


Catatan dari Perusahaan Kami

  1. Pesanan: Suku cadang medis dan aksesori dengan stok massal dan harga yang menguntungkan, dan pesanan dapat diterima dan diatur kapan saja.
  2. Pengiriman Seluruh Dunia: DHL, UPS, EMS, ACS dll, express didasarkan pada pilihan pembeli. Pesanan dapat diatur dalam 1 hari kerja setelah pembayaran dikonfirmasi. Pelacakan No. dapat ditawarkan dalam 1 hari setelah pengiriman.
  3. Ketentuan pembayaran: T / T, Western Union, Paypal dapat diterima. 100% prabayar sebelum pengiriman.
  4. Pengembalian dan perbaikan: Biaya pengiriman untuk barang yang dikembalikan harus dibebankan setengah pelanggan dan setengah penjual. Semua unit bekas akan ditangani oleh salah satu insinyur bersertifikat dan berpengalaman kami, layanan perbaikan dimungkinkan.

Merek dan Model Layanan:

GE
  • DASH1800, DASH2000, DASH2500, DASH3000, DASH4000, DASH5000
  • SOLAR8000, SOLAR8000i, SOLAR8000M
  • TRAM 400A, 451N, 451SL, 450SL, 851N, TEMP 400
  • Datex-Ohmeda, AS / 3, S / 4, S / 5, Cardiocap / 5
  • B20, B20i, B30, B40, CAM, Transport Pro, B650, B850
  • M-NESTR, M-NETPR, MP, M-EST, M-NIBP, E-PSM, E-COPSV, E-PT, E-MEM, SL-CAIO, E-NSATX, E-miniC, E-PP, E-PRESTN
  • PRO300, PRO400, PRO1000
  • EAGLE1000, EAGLE3000, EAGLE4000
  • MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90
  • M3000A, M3001A, M3012A, M3014A, M3015A, M3016A, M1013A
  • M3000-60001, M3000-60002, M3000-60003
  • A1, A3, C1, C3, M2, M3046A
  • VM4, VM6, VM8, VS3
  • MP2, MP5, IntelliVue X2
NIHON KOHDEN
  • BSM-1753, BSM-4102A, BSM-4104A, BSM-4114A
  • BSM-5135A, BSM-5136A, BSM-5106A, BSM-6301A
  • BSM-6701A, BSM-2350, BSM-2351, BSM-2351A
  • BSM-2351C, BSM-2303, BSM-2354A, BSM-2301A
  • BSM-2304A, WEP-4208A, MU-631RA
MINDRAY
  • PM-7000, PM-8000, PM-9000, MEC-1000, MEC-2000
  • PM-7000Express, PM-8000Express, VS-900
  • BeneView T5, BeneView T6, BeneView T8
  • PM-9000Express, PM-6000, PM-60, VS-600, VS-800
SPACELABS
  • 1050,90369,91369, Ultraview SL
  • 90496.91496, mCare300
SIEMENS
  • SC60002, SC6000, SC7000, SC60002XL
TYCO
  • NBP4000, NBP4000C


Layanan Perbaikan:

Perbaikan Kesalahan Umum
1. Tidak bisa boot / Tidak bisa boot 2. Modul (M3001A) tidak dapat mendeteksi tekanan darah.
3. Modul tidak dapat dihubungkan. 4. Putuskan sambungan secara otomatis.
5. Sphygmomanometer mengalami kebocoran. 6. Kegagalan peralatan NIBP.
7. Tidak dapat menghubungi. 8. Kesalahan pelaporan MMS terputus.
9. Alarm palsu MMS ditarik keluar. 10. Tidak dapat memuat.
11. Kegagalan fungsi EKG. 12. Peralatan EKG rusak.
13. Pembaruan perangkat lunak. 14. NIBP gagal mengembang.
15. Kesalahan peralatan IBP. 16. Modul M3012A tidak dapat dideteksi.
17. Secara otomatis restart. 18. Encoder tidak dapat berfungsi.
19. Layar biru muncul setelah startup. 20. Tidak ada sinyal EKG.
21. Tidak dapat masuk ke menu pilih. 22. Alarm terjadi ketika memulai, dan lampu kegagalan menyala.
23. Laporkan penyisipan CO 2 . 24. MMSL mengembangkan kesalahan modul.
25. Kesalahan modul M3015A / M3001A. 26. Tidak ada lampu layar daya.
27. Kesalahan peralatan NBP. 28. Kesalahan peralatan EKG dan oksimeter.
29. Penuaan lampu LCD. 30. Tekanan darah yang meningkat tidak menunjukkan angka.
31. Kunci plat rusak. 32. Kegagalan encoder.
33. Tidak dapat mengembang 34. Kesalahan peralatan NIBP.
35. SP O 2 dan kesalahan peralatan EKG. 36. Tidak dapat mengisi daya.
37. Layar sentuh tidak dapat berfungsi. 38. Layar menampilkan gambar ganda.
39. Kode kesalahan 1000. Kode kesalahan 20004. 40. Tidak ada alarm yang berbunyi.